Publications
Selected Publications: CMRR Engineering Group
2025 - 2020
Lagore RL, Sadeghi-Tarakameh A, Grant A, Waks M, Auerbach E, Jungst S, DelaBarre L, Moeller S, Eryaman Y, Lattanzi R, Giannakopoulos I, Vizioli L, Yacoub E, Schmidt S, Metzger GJ, Wu X, Adriany G, Uğurbil K. A 128-channel receive array with enhanced signal-to-noise ratio performance for 10.5T brain imaging. Magnetic Resonance in Medicine, 2025 Jun;93(6):2680-2698. doi: 10.1002/mrm.30476 Epub 2025 Mar 13. PMID: 40079256; PMCID: PMC11971493.
Waks, M., Lagore, R. L., Auerbach, E., Grant, A., Sadeghi‐Tarakameh, A., DelaBarre, L., . . Adriany, G.* and Uğurbil, K. (2024). RF coil design strategies for improving SNR at the ultrahigh magnetic field of 10.5T. Magnetic Resonance in Medicine, 93(2), 873-888. doi: 10.1002/mrm.30315
Woo, M. K., DelaBarre, L., Waks, M., Lagore, R., Kim, J., Jungst, S., Eryaman, Y., Ugurbil, K., Adriany, G. (2023). A 32-Channel Sleeve Antenna Receiver Array for Human Head MRI Applications at 10.5 T. IEEE transactions on medical imaging, 42(9), 2643-2652. PMID: 37030782 doi: 10.1109/TMI.2023.3261922
Sadeghi-Tarakameh, A., Jungst, S., Lanagan, M., DelaBarre, L., Wu, X., Adriany, G., Metzger, G. J., Van de Moortele, P. F., Ugurbil, K., Atalar, E., Eryaman, Y. (2022). A nine-channel transmit/receive array for spine imaging at 10.5 T: Introduction to a nonuniform dielectric substrate antenna. Magnetic Resonance in Medicine, 87(4), 2074-2088. doi: 10.1002/mrm.29096
Woo, M. K., DelaBarre, L., Waks, M., Lagore, R., Radder, J., Jungst, S., Kang, C. K., Ugurbil, K., Adriany, G. (2022). A monopole and dipole hybrid antenna array for human brain imaging at 10.5 Tesla. IEEE Antennas and Wireless Propagation Letters. doi:10.1109/LAWP.2022.3183206
Woo, M. K., Delabarre, L., Waks, M., Radder, J., Choi, U. S., Lagore, R., Ugurbil, K., Adriany, G. (2021). A 16-channel dipole antenna array for human head magnetic resonance imaging at 10.5 Tesla. Sensors, 21(21). doi: 10.3390/s21217250
Tavaf, N., Lagore, R. L., Jungst, S., Gunamony, S., Radder, J., Grant, A., Moeller, S., Auerbach, E., Ugurbil, K., Adriany, G., Van de Moortele, P. F. (2021). A self-decoupled 32-channel receive array for human-brain MRI at 10.5 T. Magnetic Resonance in Medicine, 86(3), 1759-1772. doi: 10.1002/mrm.28788
Woo, M. K., Delabarre, L., Waks, M. T., Park, Y. W., Lagore, R. L., Jungst, S., Eryaman, Y., Oh, S. H., Ugurbil, K., Adriany, G. (2021). Evaluation of 8-channel radiative antenna arrays for human head imaging at 10.5 Tesla. Sensors, 21(18). doi: 10.3390/s21186000
2020 - 2015
First 7T 64 channel coil
Uğurbil, K., Auerbach, E., Moeller, S., Grant, A., Wu, X., Van de Moortele, P. F., Olman, C., DelaBarre, L., Schillak, S., Radder, J., Lagore, R., Adriany, G. (2019). Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array. Magnetic Resonance in Medicine, 82(1), 495-509. doi: 10.1002/mrm.27695
First 10.5T NHP fMRI results
Yacoub, E., Grier, M. D., Auerbach, E. J., Lagore, R. L., Harel, N., Adriany, G., Zilverstand, A., Hayden, B. Y., Heilbronner, S. R., Uğurbil, K., Zimmermann, J. (2020). Ultra-high field (10.5 T) resting state fMRI in the macaque. NeuroImage, 223. doi: 10.1016/j.neuroimage.2020.117349
UHF 10.5T Human Safety
Grant, A., Metzger, G. J., Van de Moortele, P. F., Adriany, G., Olman, C., Zhang, L., Koopermeiners, J., Eryaman, Y., Koeritzer, M., Adams, M. E., Henry, T. R., Uğurbil, K. (2020). 10.5 T MRI static field effects on human cognitive, vestibular, and physiological function. Magnetic Resonance Imaging, 73, 163-176. doi: 10.1016/j.mri.2020.08.004
Schmitter, S., Adriany, G., Waks, M., Moeller, S., Aristova, M., Vali, A., Auerbach, E. J., Van de Moortele, P. F., Ugurbil, K., Schnell, S. (2020). Bilateral multiband 4D flow MRI of the carotid arteries at 7T. Magnetic Resonance in Medicine, 84(4), 1947-1960. doi: 10.1002/mrm.28256
First 10.5T Human Body Images
He, X., Ertürk, M. A., Grant, A., Wu, X., Lagore, R. L., DelaBarre, L., Eryaman, Y., Adriany, G., Auerbach, E. J., Van de Moortele, P. F., Uğurbil, K., Metzger, G. J. (2020). First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz. Magnetic Resonance in Medicine, 84(1), 289-303. doi: 10.1002/mrm.28131
First 10.5T Human Head Images
Sadeghi-Tarakameh, A., DelaBarre, L., Lagore, R. L., Torrado-Carvajal, A., Wu, X., Grant, A., Adriany, G., Metzger, G. J., Van de Moortele, P. F., Ugurbil, K., Atalar, E., Eryaman, Y. (2020). In vivo human head MRI at 10.5T: A radiofrequency safety study and preliminary imaging results. Magnetic Resonance in Medicine, 84(1), 484-496. doi: 10.1002/mrm.28093
Sadeghi-Tarakameh, A., Adriany, G., Metzger, G. J., Lagore, R. L., Jungst, S., DelaBarre, L., Van de Moortele, P. F., Ugurbil, K., Atalar, E., Eryaman, Y. (2020). Improving radiofrequency power and specific absorption rate management with bumped transmit elements in ultra-high field MRI. Magnetic Resonance in Medicine, 84(6), 3485-3493. doi: 10.1002/mrm.28382
Woo, M. K., Delabarre, L., Lee, B. Y., Waks, M., Lagore, R. L., Radder, J. W., Eryaman, Y., Ugurbil, K., Adriany, G. (2020). Evaluation of a 16-channel transceiver loop + dipole antenna array for human head imaging at 10.5 Tesla. IEEE Access, 8, 203555-203563. doi: 10.1109/ACCESS.2020.3036598
First 7T Loop Dipole Human Body Array
Ertürk, M. A., Raaijmakers, A. J.E., Adriany, G., Uğurbil, K., Metzger, G. J. (2017). A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI. Magnetic Resonance in Medicine, 77(2), 884-894. doi: 10.1002/mrm.26153
Selected Papers Prior 2015
First Coil Utilizing Combined Transmitters and Receivers
Adriany, G., Auerbach, E. J., Snyder, C. J., Gözübüyük, A., Moeller, S., Ritter, J., Van De Moortele, P. F., Vaughan, T., Uǧurbil, K. (2010). A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 Tesla. Magnetic Resonance in Medicine, 63(6), 1478-1485. doi: 10.1002/mrm.22413
Tkáč, I., Öz, G., Adriany, G., Uǧurbil, K., Gruetter, R. (2009). In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: Metabolite quantification at 4T vs. 7T. Magnetic Resonance in Medicine, 62(4), 868-879. doi: 10.1002/mrm.22086
First 7T Body Coil
Vaughan, J. T., Snyder, C. J., Delabarre, L. J., Bolan, P. J., Tian, J., Bolinger, L., Adriany, G., Andersen, P., Strupp, J., Ugurbil, K. (2009). Whole-body imaging at 7T: Preliminary results. Magnetic Resonance in Medicine, 61(1), 244-248. doi: 10.1002/mrm.21751
First 7T 16 Channel Transceiver Coil
Adriany, G., Van De Moortele, P. F., Ritter, J., Moeller, S., Auerbach, E. J., Akgün, C., Snyder, C. J., Vaughan, T., Uǧurbil, K. (2008). A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla. Magnetic Resonance in Medicine, 59(3), 590-597. doi: 10.1002/mrm.21488
Wiesinger, F., Van de Moortele, P. F., Adriany, G., De Zanche, N., Ugurbil, K., Pruessmann, K. P. (2006). Potential and feasibility of parallel MRI at high field. NMR in Biomedicine, 19(3), 368-378. doi: 10.1002/nbm.1050
First 9.4T Results
Vaughan, T., DelaBarre, L., Snyder, C., Tian, J., Akgun, C., Shrivastava, D., Liu, W., Olson, C., Adriany, G., Strupp, J., Andersen, P., Gopinath, A., Van De Moortele, P. F., Garwood, M., Ugurbil, K. (2006). 9.4T human MRI: Preliminary results. Magnetic Resonance in Medicine, 56(6), 1274-1282. doi: 10.1002/mrm.21073
First B1 Shimming
Van De Moortele, P. F., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., Uǧurbil, K. (2005). B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil. Magnetic Resonance in Medicine, 54(6), 1503-1518. doi: 10.1002/mrm.20708
First 7T Transceiver Arrays
Adriany, G., Van De Moortele, P. F., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., Boesiger, P., Vaughan, T., Uǧurbil, K. (2005). Transmit and receive transmission line arrays for 7 Tesla parallel imaging. Magnetic Resonance in Medicine, 53(2), 434-445. doi: 10.1002/mrm.20321
Selected Publications: Collaborators & CMRR Engineering
Zbýň Š, Ludwig KD, Watkins LE, Lagore RL, Nowacki A, Tóth F, Tompkins MA, Zhang L, Adriany G, Gold GE, Shea KG, Nagel AM, Carlson CS, Metzger GJ, Ellermann JM. Changes in tissue sodium concentration and sodium relaxation times during the maturation of human knee cartilage: Ex vivo 23 Na MRI study at 10.5 T. Magnetic Resonance in Medicine, 2024 Mar;91(3):1099-1114. doi: 10.1002/mrm.29930. Epub 2023 Nov 23. PMID: 37997011; PMCID: PMC10751033.
Zhang, B., Radder, J., Giannakopoulos, I., Grant, A., Lagore, R., Waks, M., . . Adriany, G. ,Uğurbil, K. (2024). Performance of receive head arrays versus ultimate intrinsic SNR at 7T and 10.5T. Magnetic Resonance in Medicine, 92(3), 1219-1231. PubMed Central ID Number: PMC11209800 doi: 10.1002/mrm.30108
Hingerl, L., Strasser, B., Schmidt, S., Eckstein, K., Genovese, G., Auerbach, E. J., Adriany, G. Marjańska, M. (2025). Exploring in vivo human brain metabolism at 10.5 T: Initial insights from MR spectroscopic imaging. NeuroImage, 307, 121015. doi: 10.1016/j.neuroimage.2025.121015
Colwell, Z. A., DelaBarre, L., Idiyatullin, D., Adriany, G., Garwood, M., Vaughan, J. T., Sohn, S. M. (2023). Standalone RF Self-Interference Cancellation System for In-Vivo Simultaneous Transmit and Receive (STAR) MRI. IEEE transactions on biomedical circuits and systems, 17(3), 610-620. PMID: 37171925 PMCID: PMC10393087 doi: 10.1109/TBCAS.2023.3275849
Le Ster, C., Grant, A., Van de Moortele, P. F., Monreal-Madrigal, A., Adriany, G., Vignaud, A., Mauconduit, F., Rabrait-Lerman, C., Poser, B. A., Uğurbil, K., Boulant, N. (2022). Magnetic field strength dependent SNR gain at the center of a spherical phantom and up to 11.7T. Magnetic Resonance in Medicine, 88(5), 2131-2138. doi: 10.1002/mrm.29391
Grier, M. D., Yacoub, E., Adriany, G., Lagore, R. L., Harel, N., Zhang, R. Y., Lenglet, C., Uğurbil, K., Zimmermann, J., Heilbronner, S. R. (2022). Ultra-high field (10.5T) diffusion-weighted MRI of the macaque brain. NeuroImage, 255. doi: 10.1016/j.neuroimage.2022.119200
Ozen, A. C., Idiyatullin, D., Adriany, G., Jungst, S., Kobayashi, N., Groenke, B. R., Bock, M., Garwood, M., Nixdorf, D. R. (2021). Design of an intraoral dipole antenna for dental applications. IEEE Transactions on Biomedical Engineering, 68(8), 2563-2573. doi: 10.1109/TBME.2021.3055777
Zhang, B., Adriany, G., Delabarre, L., Radder, J., Lagore, R., Rutt, B., Yang, Q. X., Ugurbil, K., Lattanzi, R. (2021). Effect of radiofrequency shield diameter on signal-to-noise ratio at ultra-high field MRI. Magnetic Resonance in Medicine, 85(6), 3522-3530. doi: 10.1002/mrm.28670
Zhang, X., Zhang, J., Gao, Y., Qian, M., Qu, S., Quan, Z., Yu, M., Chen, X., Wang, Y., Pan, G., Adriany, G., Roe, A. W. (2021). A 16-channel dense array for in vivo animal cortical MRI/fMRI on 7T human scanners. IEEE Transactions on Biomedical Engineering, 68(5), 1611-1618. doi: 10.1109/TBME.2020.3027296
Juchem, C., Theilenberg, S., Kumaragamage, C., Mullen, M., DelaBarre, L., Adriany, G., Brown, P. B., McIntyre, S., Nixon, T. W., Garwood, M., de Graaf, R. A. (2020). Dynamic multicoil technique (DYNAMITE) MRI on human brain. Magnetic Resonance in Medicine, 84(6), 2953-2963. doi: 10.1002/mrm.28323
Steensma, B., van de Moortele, P. F., Ertürk, A., Grant, A., Adriany, G., Luijten, P., Klomp, D., van den Berg, N., Metzger, G., Raaijmakers, A. (2020). Introduction of the snake antenna array: Geometry optimization of a sinusoidal dipole antenna for 10.5T body imaging with lower peak SAR. Magnetic Resonance in Medicine, 84(5), 2885-2896. doi: 10.1002/mrm.28297
Bluem, P., Van De Moortele, P. F., Adriany, G., Popovic, Z. (2019). Excitation and RF field control of a human-size 10.5-T MRI system. IEEE Transactions on Microwave Theory and Techniques, 67(3), 1184-1196. doi: 10.1109/TMTT.2018.2884405
Sengupta, S., Roebroeck, A., Kemper, V. G., Poser, B. A., Zimmermann, J., Goebel, R., Adriany, G. (2016). A specialized multi-transmit head coil for high resolution fMRI of the human visual cortex at 7T. PLoS ONE, 11(12). doi: 10.1371/journal.pone.0165418